A case of RCA CTO

TECHNIQUE OF DEEP SEATING OF CATHETER TO DELIVER STENT

  • This patient presented with total occlusion of the right coronary artery.
  • The procedure was carried out via the right radial access.

The baseline angiography shows a long blockage

rca_cto_1

2 prox balloon anchor – Due to inadequate support from the guiding catheter…

rca_cto_2

4 deep seating of guide – Very poor support from guiding catheter

Due to extreme lack of support from guiding catheter, delivery of stent was not possible. To overcome this problem, a distal anchoring balloon was deployed and extreme deep seating of guiding catheter was achieved.

rca_cto_3

Stent deployed

With the deep seating of guide, stent is able to be deployed in the RPL branch

After successful stent implantation the RCA is fully opened

CONCLUSION

  • When support of guiding catheter is inadequate.
  • The options can be to change to a different shape guide, but this will incur cost.
  • One can change to femoral approach, but this will cause extra pain and cost.
  • Deep seating of guide is commonly used, but such deep seating requires more care and skill to achieve.
  • A complex case can still be successfully completed via radial access.